public static interface UpdateSiteRackPhysicalPropertiesRequest.Builder extends OutpostsRequest.Builder, SdkPojo, CopyableBuilder<UpdateSiteRackPhysicalPropertiesRequest.Builder,UpdateSiteRackPhysicalPropertiesRequest>
| Modifier and Type | Method and Description |
|---|---|
UpdateSiteRackPhysicalPropertiesRequest.Builder |
fiberOpticCableType(FiberOpticCableType fiberOpticCableType)
Specify the type of fiber that you will use to attach the Outpost to your network.
|
UpdateSiteRackPhysicalPropertiesRequest.Builder |
fiberOpticCableType(String fiberOpticCableType)
Specify the type of fiber that you will use to attach the Outpost to your network.
|
UpdateSiteRackPhysicalPropertiesRequest.Builder |
maximumSupportedWeightLbs(MaximumSupportedWeightLbs maximumSupportedWeightLbs)
Specify the maximum rack weight that this site can support.
|
UpdateSiteRackPhysicalPropertiesRequest.Builder |
maximumSupportedWeightLbs(String maximumSupportedWeightLbs)
Specify the maximum rack weight that this site can support.
|
UpdateSiteRackPhysicalPropertiesRequest.Builder |
opticalStandard(OpticalStandard opticalStandard)
Specify the type of optical standard that you will use to attach the Outpost to your network.
|
UpdateSiteRackPhysicalPropertiesRequest.Builder |
opticalStandard(String opticalStandard)
Specify the type of optical standard that you will use to attach the Outpost to your network.
|
UpdateSiteRackPhysicalPropertiesRequest.Builder |
overrideConfiguration(AwsRequestOverrideConfiguration overrideConfiguration) |
UpdateSiteRackPhysicalPropertiesRequest.Builder |
overrideConfiguration(Consumer<AwsRequestOverrideConfiguration.Builder> builderConsumer) |
UpdateSiteRackPhysicalPropertiesRequest.Builder |
powerConnector(PowerConnector powerConnector)
Specify the power connector that Amazon Web Services should plan to provide for connections to the hardware.
|
UpdateSiteRackPhysicalPropertiesRequest.Builder |
powerConnector(String powerConnector)
Specify the power connector that Amazon Web Services should plan to provide for connections to the hardware.
|
UpdateSiteRackPhysicalPropertiesRequest.Builder |
powerDrawKva(PowerDrawKva powerDrawKva)
Specify in kVA the power draw available at the hardware placement position for the rack.
|
UpdateSiteRackPhysicalPropertiesRequest.Builder |
powerDrawKva(String powerDrawKva)
Specify in kVA the power draw available at the hardware placement position for the rack.
|
UpdateSiteRackPhysicalPropertiesRequest.Builder |
powerFeedDrop(PowerFeedDrop powerFeedDrop)
Specify whether the power feed comes above or below the rack.
|
UpdateSiteRackPhysicalPropertiesRequest.Builder |
powerFeedDrop(String powerFeedDrop)
Specify whether the power feed comes above or below the rack.
|
UpdateSiteRackPhysicalPropertiesRequest.Builder |
powerPhase(PowerPhase powerPhase)
Specify the power option that you can provide for hardware.
|
UpdateSiteRackPhysicalPropertiesRequest.Builder |
powerPhase(String powerPhase)
Specify the power option that you can provide for hardware.
|
UpdateSiteRackPhysicalPropertiesRequest.Builder |
siteId(String siteId)
Sets the value of the SiteId property for this object.
|
UpdateSiteRackPhysicalPropertiesRequest.Builder |
uplinkCount(String uplinkCount)
Racks come with two Outpost network devices.
|
UpdateSiteRackPhysicalPropertiesRequest.Builder |
uplinkCount(UplinkCount uplinkCount)
Racks come with two Outpost network devices.
|
UpdateSiteRackPhysicalPropertiesRequest.Builder |
uplinkGbps(String uplinkGbps)
Specify the uplink speed the rack should support for the connection to the Region.
|
UpdateSiteRackPhysicalPropertiesRequest.Builder |
uplinkGbps(UplinkGbps uplinkGbps)
Specify the uplink speed the rack should support for the connection to the Region.
|
buildoverrideConfigurationequalsBySdkFields, sdkFieldscopyapplyMutation, buildUpdateSiteRackPhysicalPropertiesRequest.Builder siteId(String siteId)
siteId - The new value for the SiteId property for this object.UpdateSiteRackPhysicalPropertiesRequest.Builder powerDrawKva(String powerDrawKva)
Specify in kVA the power draw available at the hardware placement position for the rack.
powerDrawKva - Specify in kVA the power draw available at the hardware placement position for the rack.PowerDrawKva,
PowerDrawKvaUpdateSiteRackPhysicalPropertiesRequest.Builder powerDrawKva(PowerDrawKva powerDrawKva)
Specify in kVA the power draw available at the hardware placement position for the rack.
powerDrawKva - Specify in kVA the power draw available at the hardware placement position for the rack.PowerDrawKva,
PowerDrawKvaUpdateSiteRackPhysicalPropertiesRequest.Builder powerPhase(String powerPhase)
Specify the power option that you can provide for hardware.
Single-phase AC feed: 200 V to 277 V, 50 Hz or 60 Hz
Three-phase AC feed: 346 V to 480 V, 50 Hz or 60 Hz
powerPhase - Specify the power option that you can provide for hardware.
Single-phase AC feed: 200 V to 277 V, 50 Hz or 60 Hz
Three-phase AC feed: 346 V to 480 V, 50 Hz or 60 Hz
PowerPhase,
PowerPhaseUpdateSiteRackPhysicalPropertiesRequest.Builder powerPhase(PowerPhase powerPhase)
Specify the power option that you can provide for hardware.
Single-phase AC feed: 200 V to 277 V, 50 Hz or 60 Hz
Three-phase AC feed: 346 V to 480 V, 50 Hz or 60 Hz
powerPhase - Specify the power option that you can provide for hardware.
Single-phase AC feed: 200 V to 277 V, 50 Hz or 60 Hz
Three-phase AC feed: 346 V to 480 V, 50 Hz or 60 Hz
PowerPhase,
PowerPhaseUpdateSiteRackPhysicalPropertiesRequest.Builder powerConnector(String powerConnector)
Specify the power connector that Amazon Web Services should plan to provide for connections to the hardware.
Note the correlation between PowerPhase and PowerConnector.
Single-phase AC feed
L6-30P – (common in US); 30A; single phase
IEC309 (blue) – P+N+E, 6hr; 32 A; single phase
Three-phase AC feed
AH530P7W (red) – 3P+N+E, 7hr; 30A; three phase
AH532P6W (red) – 3P+N+E, 6hr; 32A; three phase
powerConnector - Specify the power connector that Amazon Web Services should plan to provide for connections to the
hardware. Note the correlation between PowerPhase and PowerConnector.
Single-phase AC feed
L6-30P – (common in US); 30A; single phase
IEC309 (blue) – P+N+E, 6hr; 32 A; single phase
Three-phase AC feed
AH530P7W (red) – 3P+N+E, 7hr; 30A; three phase
AH532P6W (red) – 3P+N+E, 6hr; 32A; three phase
PowerConnector,
PowerConnectorUpdateSiteRackPhysicalPropertiesRequest.Builder powerConnector(PowerConnector powerConnector)
Specify the power connector that Amazon Web Services should plan to provide for connections to the hardware.
Note the correlation between PowerPhase and PowerConnector.
Single-phase AC feed
L6-30P – (common in US); 30A; single phase
IEC309 (blue) – P+N+E, 6hr; 32 A; single phase
Three-phase AC feed
AH530P7W (red) – 3P+N+E, 7hr; 30A; three phase
AH532P6W (red) – 3P+N+E, 6hr; 32A; three phase
powerConnector - Specify the power connector that Amazon Web Services should plan to provide for connections to the
hardware. Note the correlation between PowerPhase and PowerConnector.
Single-phase AC feed
L6-30P – (common in US); 30A; single phase
IEC309 (blue) – P+N+E, 6hr; 32 A; single phase
Three-phase AC feed
AH530P7W (red) – 3P+N+E, 7hr; 30A; three phase
AH532P6W (red) – 3P+N+E, 6hr; 32A; three phase
PowerConnector,
PowerConnectorUpdateSiteRackPhysicalPropertiesRequest.Builder powerFeedDrop(String powerFeedDrop)
Specify whether the power feed comes above or below the rack.
powerFeedDrop - Specify whether the power feed comes above or below the rack.PowerFeedDrop,
PowerFeedDropUpdateSiteRackPhysicalPropertiesRequest.Builder powerFeedDrop(PowerFeedDrop powerFeedDrop)
Specify whether the power feed comes above or below the rack.
powerFeedDrop - Specify whether the power feed comes above or below the rack.PowerFeedDrop,
PowerFeedDropUpdateSiteRackPhysicalPropertiesRequest.Builder uplinkGbps(String uplinkGbps)
Specify the uplink speed the rack should support for the connection to the Region.
uplinkGbps - Specify the uplink speed the rack should support for the connection to the Region.UplinkGbps,
UplinkGbpsUpdateSiteRackPhysicalPropertiesRequest.Builder uplinkGbps(UplinkGbps uplinkGbps)
Specify the uplink speed the rack should support for the connection to the Region.
uplinkGbps - Specify the uplink speed the rack should support for the connection to the Region.UplinkGbps,
UplinkGbpsUpdateSiteRackPhysicalPropertiesRequest.Builder uplinkCount(String uplinkCount)
Racks come with two Outpost network devices. Depending on the supported uplink speed at the site, the Outpost
network devices provide a variable number of uplinks. Specify the number of uplinks for each Outpost network
device that you intend to use to connect the rack to your network. Note the correlation between
UplinkGbps and UplinkCount.
1Gbps - Uplinks available: 1, 2, 4, 6, 8
10Gbps - Uplinks available: 1, 2, 4, 8, 12, 16
40 and 100 Gbps- Uplinks available: 1, 2, 4
uplinkCount - Racks come with two Outpost network devices. Depending on the supported uplink speed at the site, the
Outpost network devices provide a variable number of uplinks. Specify the number of uplinks for each
Outpost network device that you intend to use to connect the rack to your network. Note the
correlation between UplinkGbps and UplinkCount.
1Gbps - Uplinks available: 1, 2, 4, 6, 8
10Gbps - Uplinks available: 1, 2, 4, 8, 12, 16
40 and 100 Gbps- Uplinks available: 1, 2, 4
UplinkCount,
UplinkCountUpdateSiteRackPhysicalPropertiesRequest.Builder uplinkCount(UplinkCount uplinkCount)
Racks come with two Outpost network devices. Depending on the supported uplink speed at the site, the Outpost
network devices provide a variable number of uplinks. Specify the number of uplinks for each Outpost network
device that you intend to use to connect the rack to your network. Note the correlation between
UplinkGbps and UplinkCount.
1Gbps - Uplinks available: 1, 2, 4, 6, 8
10Gbps - Uplinks available: 1, 2, 4, 8, 12, 16
40 and 100 Gbps- Uplinks available: 1, 2, 4
uplinkCount - Racks come with two Outpost network devices. Depending on the supported uplink speed at the site, the
Outpost network devices provide a variable number of uplinks. Specify the number of uplinks for each
Outpost network device that you intend to use to connect the rack to your network. Note the
correlation between UplinkGbps and UplinkCount.
1Gbps - Uplinks available: 1, 2, 4, 6, 8
10Gbps - Uplinks available: 1, 2, 4, 8, 12, 16
40 and 100 Gbps- Uplinks available: 1, 2, 4
UplinkCount,
UplinkCountUpdateSiteRackPhysicalPropertiesRequest.Builder fiberOpticCableType(String fiberOpticCableType)
Specify the type of fiber that you will use to attach the Outpost to your network.
fiberOpticCableType - Specify the type of fiber that you will use to attach the Outpost to your network.FiberOpticCableType,
FiberOpticCableTypeUpdateSiteRackPhysicalPropertiesRequest.Builder fiberOpticCableType(FiberOpticCableType fiberOpticCableType)
Specify the type of fiber that you will use to attach the Outpost to your network.
fiberOpticCableType - Specify the type of fiber that you will use to attach the Outpost to your network.FiberOpticCableType,
FiberOpticCableTypeUpdateSiteRackPhysicalPropertiesRequest.Builder opticalStandard(String opticalStandard)
Specify the type of optical standard that you will use to attach the Outpost to your network. This field is dependent on uplink speed, fiber type, and distance to the upstream device. For more information about networking requirements for racks, see Network in the Amazon Web Services Outposts User Guide.
OPTIC_10GBASE_SR: 10GBASE-SR
OPTIC_10GBASE_IR: 10GBASE-IR
OPTIC_10GBASE_LR: 10GBASE-LR
OPTIC_40GBASE_SR: 40GBASE-SR
OPTIC_40GBASE_ESR: 40GBASE-ESR
OPTIC_40GBASE_IR4_LR4L: 40GBASE-IR (LR4L)
OPTIC_40GBASE_LR4: 40GBASE-LR4
OPTIC_100GBASE_SR4: 100GBASE-SR4
OPTIC_100GBASE_CWDM4: 100GBASE-CWDM4
OPTIC_100GBASE_LR4: 100GBASE-LR4
OPTIC_100G_PSM4_MSA: 100G PSM4 MSA
OPTIC_1000BASE_LX: 1000Base-LX
OPTIC_1000BASE_SX : 1000Base-SX
opticalStandard - Specify the type of optical standard that you will use to attach the Outpost to your network. This
field is dependent on uplink speed, fiber type, and distance to the upstream device. For more
information about networking requirements for racks, see Network in the Amazon Web Services Outposts User Guide.
OPTIC_10GBASE_SR: 10GBASE-SR
OPTIC_10GBASE_IR: 10GBASE-IR
OPTIC_10GBASE_LR: 10GBASE-LR
OPTIC_40GBASE_SR: 40GBASE-SR
OPTIC_40GBASE_ESR: 40GBASE-ESR
OPTIC_40GBASE_IR4_LR4L: 40GBASE-IR (LR4L)
OPTIC_40GBASE_LR4: 40GBASE-LR4
OPTIC_100GBASE_SR4: 100GBASE-SR4
OPTIC_100GBASE_CWDM4: 100GBASE-CWDM4
OPTIC_100GBASE_LR4: 100GBASE-LR4
OPTIC_100G_PSM4_MSA: 100G PSM4 MSA
OPTIC_1000BASE_LX: 1000Base-LX
OPTIC_1000BASE_SX : 1000Base-SX
OpticalStandard,
OpticalStandardUpdateSiteRackPhysicalPropertiesRequest.Builder opticalStandard(OpticalStandard opticalStandard)
Specify the type of optical standard that you will use to attach the Outpost to your network. This field is dependent on uplink speed, fiber type, and distance to the upstream device. For more information about networking requirements for racks, see Network in the Amazon Web Services Outposts User Guide.
OPTIC_10GBASE_SR: 10GBASE-SR
OPTIC_10GBASE_IR: 10GBASE-IR
OPTIC_10GBASE_LR: 10GBASE-LR
OPTIC_40GBASE_SR: 40GBASE-SR
OPTIC_40GBASE_ESR: 40GBASE-ESR
OPTIC_40GBASE_IR4_LR4L: 40GBASE-IR (LR4L)
OPTIC_40GBASE_LR4: 40GBASE-LR4
OPTIC_100GBASE_SR4: 100GBASE-SR4
OPTIC_100GBASE_CWDM4: 100GBASE-CWDM4
OPTIC_100GBASE_LR4: 100GBASE-LR4
OPTIC_100G_PSM4_MSA: 100G PSM4 MSA
OPTIC_1000BASE_LX: 1000Base-LX
OPTIC_1000BASE_SX : 1000Base-SX
opticalStandard - Specify the type of optical standard that you will use to attach the Outpost to your network. This
field is dependent on uplink speed, fiber type, and distance to the upstream device. For more
information about networking requirements for racks, see Network in the Amazon Web Services Outposts User Guide.
OPTIC_10GBASE_SR: 10GBASE-SR
OPTIC_10GBASE_IR: 10GBASE-IR
OPTIC_10GBASE_LR: 10GBASE-LR
OPTIC_40GBASE_SR: 40GBASE-SR
OPTIC_40GBASE_ESR: 40GBASE-ESR
OPTIC_40GBASE_IR4_LR4L: 40GBASE-IR (LR4L)
OPTIC_40GBASE_LR4: 40GBASE-LR4
OPTIC_100GBASE_SR4: 100GBASE-SR4
OPTIC_100GBASE_CWDM4: 100GBASE-CWDM4
OPTIC_100GBASE_LR4: 100GBASE-LR4
OPTIC_100G_PSM4_MSA: 100G PSM4 MSA
OPTIC_1000BASE_LX: 1000Base-LX
OPTIC_1000BASE_SX : 1000Base-SX
OpticalStandard,
OpticalStandardUpdateSiteRackPhysicalPropertiesRequest.Builder maximumSupportedWeightLbs(String maximumSupportedWeightLbs)
Specify the maximum rack weight that this site can support. NO_LIMIT is over 2000lbs.
maximumSupportedWeightLbs - Specify the maximum rack weight that this site can support. NO_LIMIT is over 2000lbs.MaximumSupportedWeightLbs,
MaximumSupportedWeightLbsUpdateSiteRackPhysicalPropertiesRequest.Builder maximumSupportedWeightLbs(MaximumSupportedWeightLbs maximumSupportedWeightLbs)
Specify the maximum rack weight that this site can support. NO_LIMIT is over 2000lbs.
maximumSupportedWeightLbs - Specify the maximum rack weight that this site can support. NO_LIMIT is over 2000lbs.MaximumSupportedWeightLbs,
MaximumSupportedWeightLbsUpdateSiteRackPhysicalPropertiesRequest.Builder overrideConfiguration(AwsRequestOverrideConfiguration overrideConfiguration)
overrideConfiguration in interface AwsRequest.BuilderUpdateSiteRackPhysicalPropertiesRequest.Builder overrideConfiguration(Consumer<AwsRequestOverrideConfiguration.Builder> builderConsumer)
overrideConfiguration in interface AwsRequest.BuilderCopyright © 2021. All rights reserved.